Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Adv Prosthodont ; 15(2): 55-62, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37153006

RESUMO

PURPOSE: The aim of this study is to evaluate the accuracy of removable partial denture (RPD) frameworks produced using different digital protocols. MATERIALS AND METHODS: 80 frameworks for RPDs were produced using CAD-CAM technology and divided into four groups of twenty (n = 20): Group 1, Titanium frameworks manufactured by digital metal laser sintering (DMLS); Group 2, Co-Cr frameworks manufactured by DMLS; Group 3, Polyamide PA12 castable resin manufactured by multi-jet fusion (MJF); and Group 4, Metal (Co-Cr) casting by using lost-wax technique. After the digital acquisition, eight specific areas were selected in order to measure the Δ-error value at the intaglio surface of RPD. The minimum value required for point sampling density (0.4 mm) was derived from the sensitivity analysis. The obtained Δ-error mean value was used for comparisons: 1. between different manufacturing processes; 2. between different manufacturing techniques in the same area of interest (AOI); and 3. between different AOI of the same group. RESULTS: The Δ-error mean value of each group ranged between -0.002 (Ti) and 0.041 (Co-Cr) mm. The Pearson's Chi-squared test revealed significant differences considering all groups paired two by two, except for group 3 and 4. The multiple comparison test documented a significant difference for each AOI among group 1, 3, and 4. The multiple comparison test showed significant differences among almost all different AOIs of each group. CONCLUSION: All Δ-mean error values of all digital protocols for manufacturing RPD frameworks optimally fit within the clinical tolerance limit of trueness and precision.

2.
J Adv Prosthodont ; 15(1): 22-32, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36908755

RESUMO

PURPOSE: Digital technology has enabled improvements in the fitting accuracy of denture bases via milling techniques. The aim of this study was to evaluate the trueness and precision of digital and analog techniques for manufacturing complete dentures (CDs). MATERIALS AND METHODS: Sixty identical CDs were manufactured using different production protocols. Digital and analog technologies were compared using the reference geometric approach, and the Δ-error values of eight areas of interest (AOI) were calculated. For each AOI, a precise number of measurement points was selected according to sensitivity analyses to compare the Δ-error of trueness and precision between the original model and manufactured prosthesis. Three types of statistical analysis were performed: to calculate the intergroup cumulative difference among the three protocols, the intergroup among the AOIs, and the intragroup difference among AOIs. RESULTS: There was a statistically significant difference between the dentures made using the oversize process and injection molding process (P < .001), but no significant difference between the other two manufacturing methods (P = .1227). There was also a statistically significant difference between the dentures made using the monolithic process and the other two processes for all AOIs (P = .0061), but there was no significant difference between the other two processes (P = 1). Within each group, significant differences among the AOIs were observed. CONCLUSION: The monolithic process yielded better results, in terms of accuracy (trueness and precision), than the other groups, although all three processes led to dentures with Δ-error values well within the clinical tolerance limit.

3.
Materials (Basel) ; 16(2)2023 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-36676557

RESUMO

Material extrusion additive manufacturing enables us to combine more materials in the same nozzle during the deposition process. This technology, called material coextrusion, generates an expanded range of material properties, which can gradually change in the design domain, ensuring blending or higher bonding/interlocking among the different materials. To exploit the opportunities offered by these technologies, it is necessary to know the behavior of the combined materials according to the materials fractions. In this work, two compatible pairs of materials, namely Polylactic Acid (PLA)-Thermoplastic Polyurethane (TPU) and Acrylonitrile Styrene Acrylate (ASA)-TPU, were investigated by changing the material fractions in the coextrusion process. An original model describing the distribution of the materials is proposed. Based on this, the mechanical properties were investigated by analytical and numerical approaches. The analytical model was developed on the simplified assumption that the coextruded materials are a set of rods, whereas the more realistic numerical model is based on homogenization theory, adopting the finite element analysis of a representative volume element. To verify the deposition model, a specific experimental test was developed, and the modeled material deposition was superimposed and qualitatively compared with the actual microscope images regarding the different deposition directions and material fractions. The analytical and numerical models show similar trends, and it can be assumed that the finite element model has a more realistic behavior due to the higher accuracy of the model description. The elastic moduli obtained by the models was verified in experimental tensile tests. The tensile tests show Young's moduli of 3425 MPa for PLA, 1812 MPa for ASA, and 162 MPa for TPU. At the intermediate material fraction, the Young's modulus shows an almost linear trend between PLA and TPU and between ASA and TPU. The ultimate tensile strength values are 63.9 MPa for PLA, 35.7 MPa for ASA, and 63.5 MPa for TPU, whereas at the intermediate material fraction, they assume lower values. In this initial work, the results show a good agreement between models and experiments, providing useful tools for designers and contributing to a new branch in additive manufacturing research.

4.
Artigo em Inglês | MEDLINE | ID: mdl-35457583

RESUMO

Background: We compare the accuracy of new intraoral scanners (IOSs) in full-arch digital implant impressions. Methods: A master model with six scan bodies was milled in poly(methyl methacrylate), measured by using a coordinate measuring machine, and scanned 15 times with four IOSs: PrimeScan, Medit i500, Vatech EZ scan, and iTero. The software was developed to identify the position points on each scan body. The 3D position and distance analysis were performed. Results: The average and ± standard deviation of the 3D position analysis was 29 µm ± 6 µm for PrimeScan, 39 µm ± 6 µm for iTero, 48 µm ± 18 µm for Mediti500, and 118 µm ± 24 µm for Vatech EZ scan (p < 0.05). Conclusions: All IOSs are able to make a digital complete implant impression in vitro according to the average misfit value reported in literature (150 µm); however, the 3D distance analysis showed that only the Primescan and iTero presented negligible systematic error sources.


Assuntos
Desenho Assistido por Computador , Modelos Dentários , Imageamento Tridimensional , Próteses e Implantes , Projetos de Pesquisa
5.
J Prosthodont Res ; 66(3): 502-508, 2022 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-34853238

RESUMO

PURPOSE: To compare the flexural properties and the adhesion of Lactobacillus salivarius (LS), Streptococcus mutans (SM), and Candida albicans (CA) on heat-polymerized (CV), CAD-CAM milled (CAD), or 3D-printed (3D) Poly (methylmethacrylate) (PMMA). METHODS: Ultimate Flexural Strength (UFS), Flexural Strain (FS) (%) at Flexural Strength, and Flexural Modulus (FM) of specimens (65.0×10.0×3.3 mm) from each PMMA group (n=6) were calculated by using the 3-point bending test. The surface roughness profiles (R) were measured before and after polishing with a contact profilometer. LS, SM, and CA adhesion on PMMA specimens (n=18) (10 mm in diameter, 3 mm in height) was assessed after 90 minutes and 16 hours by using scanning electron microscopy. The Kruskal-Wallis test with post hoc analysis was performed to compare the groups (alpha=0.05). RESULTS: Mean UFS values were 80.79±7.64 MPa for CV, 110.23±5.03 MPa for CAD, and 87.34±6.39 MPa for 3D. Mean FS values were 4.37±1.04% for CV, 4.71±0.62% for CAD, and 6.19±0.13 % for 3D. Mean FM values were 2542±301 MPa for CV, 3435±346 MPa for CAD, and 2371±197 MPa for 3D. CAD had the lowest average R value (0.29±0.16 µm) before polishing, and bacterial adhesion after 90 minutes of incubation. R value and microbial adhesion were not different amongst groups after polishing and 16 hours of incubation, respectively. CONCLUSION: The CAD group displayed the best flexural properties, except for FS, the lowest roughness before polishing and bacterial adhesion after 90 minutes of incubation. All tested PMMAs had similar surface roughness after polishing, and microbial adhesion after 16 hours of incubation.


Assuntos
Bases de Dentadura , Polimetil Metacrilato , Temperatura Alta , Teste de Materiais , Impressão Tridimensional , Propriedades de Superfície
6.
J Prosthet Dent ; 126(6): 763-771, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33526247

RESUMO

STATEMENT OF PROBLEM: New polyvinyl siloxane (PVS) materials with enhanced properties have been developed to improve and facilitate implant impression techniques. However, studies on their accuracy are lacking. PURPOSE: The purpose of this in vitro study was to determine the accuracy and precision of implant impressions made with some recently introduced materials on a simulated patient requiring an all-on-4 implant-supported prosthesis. Well-established polyether materials were also evaluated as a comparison. The variables considered were material type, consistency, splinting or not splinting techniques, and implant angulation. MATERIAL AND METHODS: A reference master model was made by inserting 4 implants at angles of 0, 5, and 10 degrees. Eighty impressions were made at 37 °C in wet conditions by using a standardized technique. Eight groups (n=10) were created using monophasic, single-viscosity materials (Hydrorise Implant Medium, HIM-ns; Hydrorise Implant Medium, HIM; Honigum Mono, HM; Impregum, IMP), and 2-viscosity materials (Hydrorise Implant Heavy+Light-ns, HIH+L-ns; Hydrorise Implant Heavy+Light, HIH+L; Honigum Heavy+Light, HH+L; and Permadyne and Garant [Heavy+Light, PeH+L]). Hydrorise materials were used with splinting and not splinting (ns) techniques. The reference points located on the connecting platforms of the transfer copings (TCP) were compared with the same points on the implant connecting platforms (ICP) located in the reference model. The accuracy and precision of the impressions were determined as linear 3D errors and standard deviation between each TCP-ICP couple by using an optical coordinate measuring machine (OCMM). RESULTS: PVS materials were generally better than polyether materials, with Hydrorise materials (HIM and HIH+L) showing significantly better accuracy and precision (30.9 ±14.4 µm and 28.7 ±15.5 µm, respectively) than IMP and PeH+L polyethers (44.2 ±16 µm and 43.8 ±17.6 µm, respectively; P<.001). Honigum materials were statistically similar to Hydrorise materials (P=.765). The values shown by Hydrorise nonsplinted groups (HIH+L-ns and HIM-ns) were not statistically different from those of the splinted polyether impressions (P=.386). The viscosities (monophasic or heavy+light) had no effect on accuracy, but monophasic material positively influenced precision (HIM and HIH+L, P=.001). No correlation was found between implant angulation and accuracy (multilevel analysis and Kendall rank correlation coefficient=-0.065; P=.133). CONCLUSIONS: Recently introduced materials designed for implant impressions showed significantly higher accuracy and precision; even with the unfavorable nonsplinting technique, the new materials performed similarly to, or better than, polyether materials. Although the transfer coping splinting technique generally improved the accuracy and precision of Hydrorise materials, the effect was significant only within HIH+L groups.


Assuntos
Implantes Dentários , Técnica de Moldagem Odontológica , Materiais para Moldagem Odontológica , Humanos , Modelos Dentários
7.
Clin Oral Implants Res ; 32(3): 324-336, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33341106

RESUMO

OBJECTIVES: Implantoplasty (IP) is a treatment option for peri-implantitis. Mechanical concerns were raised on fracture resistance of implants subjected to this procedure. This study aimed to compare two methods of IP in terms of implant wear and fracture resistance, and of surface topography. MATERIAL AND METHODS: Eighteen cylindrical screw-shaped dental implants (4 mm diameter, 13 mm length) with an external hexagonal connection were used. IP was performed on the first 6-mm implant surface with a sequence of burs or diamond sonic tips, both followed by an Arkansas finishing. IP duration and implant weight variation were recorded. Micro-computed tomography (micro-CT) was used to evaluate material loss. Implant fracture resistance was assessed by static compression test. Surface topography analysis was performed with a stylus profilometer. Scanning electron microscopy-energy dispersive X-ray spectroscopy (SEM-EDS) was applied for implant surface morphology and elemental characterization. RESULTS: Micro-CT showed less material loss in sonic compared to burs. No statistically significant difference was found between the mean fracture resistance values reached in bur and sonic, both followed by Arkansas, and with respect to control. IP performed with burs led to a smoother surface compared to sonic. Equivalent final surface roughness was found after Arkansas in both IP procedures. SEM-EDS showed a deburring effect associated to sonic and revealed carbon and aluminum peaks attributable to contamination with sonic diamond tips and Arkansas bur, respectively. CONCLUSIONS: IP with sonic diamond tips was found to be more conservative in terms of structure loss. This could have a clinical relevance in case of narrow-diameter implants.


Assuntos
Polimento Dentário , Diamante , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Microtomografia por Raio-X
8.
J Prosthet Dent ; 124(1): 75-80, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31732093

RESUMO

STATEMENT OF PROBLEM: The marginal gap and ceramic bond strength of metal-ceramic restorations are important for success. However, studies evaluating the marginal gap and ceramic bond strength of fixed partial dentures (FPDs) produced with 3D printing technologies such as selective laser melting (SLM) are scarce. PURPOSE: The purpose of this in vitro study was to investigate the marginal gap of cobalt-chromium (Co-Cr) alloy frameworks produced by SLM technology before and after ceramic firing. Additionally, the metal-ceramic bond strength was evaluated with the Schwickerath crack-initiation test according to the International Standards Organization (ISO) 9693-1:2012. MATERIAL AND METHODS: Conventional impressions were made, and the definitive cast of a patient requiring a 4-unit FPD was scanned. After designing the FPD, the files were sent to a service center for the fabrication of a metal master model, 80 Co-Cr frameworks, and 80 flat specimens (25×3×0.5 mm) with SLM technology. The marginal gap between frameworks and the abutment tooth of the metal master model was nondestructively measured by using an optical coordinate-measuring machine. A total of 80 sets, consisting of 1 framework and 1 flat specimen, were sent to 80 dental laboratory technicians for ceramic firing. Detailed instructions for correct manipulation of the framework and flat specimen were provided. The marginal gap was remeasured, and the 3-point bend test was used to evaluate metal-ceramic bond strength. RESULTS: Only 28 of the 80 dental technicians returned the specimens within a prespecified time and/or in adequate condition. The mean ±standard deviation marginal gap of the framework before ceramic firing was 25 ±9 µm and 34 ±12 µm after firing. The difference was statistically significant (P=.001). The mean ±standard deviation 3-point bend strength was 33 ±9 MPa. CONCLUSIONS: Ceramic firing affected the marginal gap; however, all Co-Cr frameworks had a marginal gap lower than 120 µm, which is reported to be a clinically acceptable limit. Most of the specimens (80%) had a metal-ceramic bond strength value higher than the 25-MPa ISO 9693 requirement. Five of 28 dental laboratory technicians were not able to comply with ceramic firing instructions.


Assuntos
Cobalto , Técnica de Fundição Odontológica , Cerâmica , Cromo , Ligas de Cromo , Porcelana Dentária , Humanos , Teste de Materiais , Ligas Metalo-Cerâmicas , Impressão Tridimensional , Propriedades de Superfície
9.
Vet Rec ; 185(14): 443, 2019 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-31292274

RESUMO

AIMS: The purpose of the study was to evaluate the accuracy of a three-dimensional (3D) automated technique (computer-aided design (aCAD)) for the measurement of three canine femoral angles: anatomical lateral distal femoral angle (aLDFA), femoral neck angle (FNA) and femoral torsion angle. METHODS: Twenty-eight femurs equally divided intotwo groups (normal and abnormal) were obtained from 14 dogs of different conformations (dolicomorphic and chondrodystrophicCT scans and 3D scanner acquisitions were used to create stereolithographic (STL) files , which were run in a CAD platform. Two blinded observers separately performed the measurements using the STL obtained from CT scans (CT aCAD) and 3D scanner (3D aCAD), which was considered the gold standard method. C orrelation coefficients were used to investigate the strength of the relationship between the two measurements. RESULTS: A ccuracy of the aCAD computation was good, being always above the threshold of R2 of greater than 80 per cent for all three angles assessed in both groups. a LDFA and FNA were the most accurate angles (accuracy >90 per cent). CONCLUSIONS: The proposed 3D aCAD protocol can be considered a reliable technique to assess femoral angle measurements in canine femur. The developed algorithm automatically calculates the femoral angles in 3D, thus considering the subjective intrinsic femur morphology. The main benefit relies on a fast user-independent computation, which avoids user-related measurement variability. The accuracy of 3D details may be helpful for patellar luxation and femoral bone deformity correction, as well as for the design of patient- specific, custom-made hip prosthesis implants.


Assuntos
Fêmur/anatomia & histologia , Fêmur/diagnóstico por imagem , Imageamento Tridimensional/veterinária , Tomografia Computadorizada por Raios X/veterinária , Animais , Cães , Feminino , Masculino , Reprodutibilidade dos Testes
10.
J Prosthodont ; 28(5): 556-563, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31038248

RESUMO

PURPOSE: To determine the trueness and precision of frameworks manufactured with a selective laser melting/milling hybrid technique (SLM/m) and conventional milling by comparing the implant-platform/framework interface with those of the original computer-aided design (CAD). MATERIALS AND METHODS: Using a virtual 6-implant-supported full-arch framework CAD drawing, 27 titanium replicas were manufactured by 3 independent manufacturing centers (n = 9/center) using a hybrid SLM/m technology (labs 1 and 2) or the conventional milling technique (lab 3). Using an opto-mechanical coordinate measuring machine, the frameworks' misfit distribution and patterns were analyzed, and the position error between paired platform positions within each framework was evaluated to calculate the misfit tendency for each group. A multilevel analysis using a mixed-effects model was conducted (α = 0.05). The trueness was evaluated as the dimensional difference from the original, while the precision as the dimensional difference from a repeated scan. RESULTS: The 3 dimensional misfits differed significantly among the 3 groups, with the milled group exhibiting the least accurate outcome (p = 0.005). The mean 3D positioning errors ranged from 8 to 16 µm and from 9 to 22 µm for the SLM/m technique (labs 1 and 2, respectively), and from 20 to 35 µm for conventional milling (lab 3). Regarding the misfit distribution pattern, the misfit increased with the distance between paired platform positions in all groups. CONCLUSIONS: All groups had 3D misfits well within the error limits reported in the literature. The 3D misfits of new hybrid (SLM/milling) and conventional (milling) procedures differed significantly among them, with the milling technique the less accurate and precise. The largest errors in all groups were found between the most distant implants, resulting in a correlation between the framework span and the inaccuracies.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Parafusos Ósseos , Desenho Assistido por Computador , Planejamento de Prótese Dentária , Titânio
11.
J Prosthodont Res ; 63(4): 396-403, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31072730

RESUMO

PURPOSE: Compare the accuracy of intraoral digital impression in full-arch implant-supported fixed dental prosthesis acquired with eight different intraoral scanner (Ios). METHODS: A polymethyl methacrylate acrylic model of an edentulous mandible with six scan-abutment was used as a master model and its dimensions measured with a coordinate measuring machine. Eight different Ios were used to generate digital impression: True Definition, Trios, Cerec Omnicam, 3D progress, CS3500, CS3600, Planmeca Emelard and Dental Wings. Fifteen digital impressions were made. A software called "Scan-abut" was developed to analyse and compare the digital impression with the master model, obtaining the scanning accuracy. The three-dimensional (3D) position and distance analysis were performed. RESULTS: Mean value of the 3D position analysis showed that the True Definition (31 µm ± 8 µm) and Trios (32 µm ± 5 µm) have the best performance of the group. The Cerec Omnicam (71 µm ± 55 µm), CS3600 (61 µm ± 14 µm) have an average performance. The CS3500 (107 µm ± 28 µm) and Planmeca Emelard (101 µm ± 38 µm) present a middle-low performance, while the 3D progress (344 µm ± 121 µm) and Dental Wings (148 µm ± 64 µm) show the low performance. The 3D distance analysis showed a good linear relationship between the errors and scan-abutment distance only with the True Definition and CS3600. CONCLUSIONS: Not all scanners are suitable for digital impression in full-arch implant-supported fixed dental prosthesis and the weight of the output files is independent from the accuracy of the Ios.


Assuntos
Técnica de Moldagem Odontológica , Modelos Dentários , Desenho Assistido por Computador , Planejamento de Prótese Dentária , Imageamento Tridimensional
12.
PLoS One ; 13(6): e0199591, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29944716

RESUMO

Improving soft tissue attachment and reducing bacterial colonization on titanium abutments are key factors for the long-term maintenance of healthy soft and hard peri-implant tissues. This in vitro study was conducted to compare the biocompatibility and antibacterial activity of four different surfaces: uncoated Ti6Al4V, anodized, and coated with titanium nitride or zirconium nitride. Surface topography was investigated with a high-resolution system for measuring surface finishes. Human gingival fibroblast (HGF) adhesion and proliferation were examined using MTT assay, Scanning Electron Microscopy (SEM) imaging, immunofluorescence analysis and real-time PCR for selected target genes. The hemolysis and AMES tests were performed to assess the chemical compounds' blood compatibility and mutagenic potential, respectively. Antibacterial activity was tested against five bacterial strains isolated from the oral cavity (Streptococcus salivarius, S. sanguinis, S. mutans, S. sobrinus, S. oralis), and the percentage of dead bacteria was calculated. Roughness measurements confirmed a substantial similarity between the surfaces and their compatibility with clinical applications. MTT assay, SEM analysis and immunofluorescence staining showed adhesion and proliferation of HGFs cultured on all the examined surfaces. PCR confirmed that HGFs produced extracellular matrix components efficiently on all the surfaces. No hemolytic activity was detected, and the AMES test confirmed the surfaces' clinical safety. For all tested bacterial strains, biofilms grown on the zirconium nitride surface showed a higher percentage of dead bacteria than on the other disks. The titanium nitride surface inactivated bacterial biofilms, too, but to a lesser extent.


Assuntos
Materiais Revestidos Biocompatíveis , Dente Suporte/microbiologia , Titânio , Zircônio , Ligas , Antibacterianos , Biofilmes/crescimento & desenvolvimento , Adesão Celular , Proliferação de Células , Células Cultivadas , Fibroblastos/citologia , Fibroblastos/fisiologia , Gengiva/citologia , Gengiva/fisiologia , Humanos , Teste de Materiais , Streptococcus/crescimento & desenvolvimento , Streptococcus/fisiologia , Propriedades de Superfície
13.
Appl Bionics Biomech ; 2018: 1654782, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29487626

RESUMO

Advances in additive manufacturing technologies facilitate the fabrication of cellular materials that have tailored functional characteristics. The application of solid freeform fabrication techniques is especially exploited in designing scaffolds for tissue engineering. In this review, firstly, a classification of cellular materials from a geometric point of view is proposed; then, the main approaches on geometric modeling of cellular materials are discussed. Finally, an investigation on porous scaffolds fabricated by additive manufacturing technologies is pointed out. Perspectives in geometric modeling of scaffolds for tissue engineering are also proposed.

14.
Int J Comput Assist Radiol Surg ; 13(7): 1097-1108, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29500759

RESUMO

PURPOSE: This study describes a method for measuring the accuracy of the virtual impression. METHODS: In vitro measurements according to a metrological approach were based on (1) use of an opto-mechanical coordinate measuring machine to acquire 3D points from a master model, (2) the mathematical reconstruction of regular geometric features (planes, cylinders, points) from 3D points or an STL file, and (3) consistent definition and evaluation of position and distance errors describing scanning inaccuracies. Two expert and two inexpert operators each made five impressions. The 3D position error, with its relevant X, Y, and Z components, the mean 3D position error of each scanbody, and the intra-scanbody distance error were measured using the analysis of variance and the Sheffe's test for multiple comparison. RESULTS: Statistically significant differences in the accuracy of the impression were observed among the operators for each scanbody, despite the good reliability (Cronbach's [Formula: see text] = 0.897). The mean 3D position error of the digital impression was between 0.041 ± 0.023 mm and 0.082 ± 0.030 mm. CONCLUSIONS: Within the limitations of this in vitro study, which was performed using a single commercial system for preparing digital impressions and one test configuration, the data showed that the digital impressions had a level of accuracy comparable to that reported in other studies, and which was acceptable for clinical and technological applications. The distance between the individual positions (#36 to #46) of the scanbody influenced the magnitude of the error. The position error generated by the intraoral scanner was dependent on the length of the arch scanned. Operator skill and experience may influence the accuracy of the impression.


Assuntos
Desenho Assistido por Computador , Implantes Dentários , Técnica de Moldagem Odontológica , Imageamento Tridimensional/métodos , Materiais para Moldagem Odontológica , Humanos , Modelos Dentários , Reprodutibilidade dos Testes
15.
Int J Oral Maxillofac Implants ; 33(1): 23-30, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29340342

RESUMO

PURPOSE: The aim of this in vitro study was to verify whether or not stock and computer-aided design/computer-aided manufacturing (CAD/CAM) abutments show similar precision in the connection with the respective implants. MATERIALS AND METHODS: Ten CAD/CAM titanium abutments were compared with 10 stock titanium abutments. Each abutment fit a regular-platform implant (Institute Straumann). Implants and abutments were measured independently and then connected. During the connection procedure, the torque was measured using a six-axes load cell. Then, outer geometric features of the implant-abutment connection were measured again. Finally, the assembly was sectioned to provide the analysis of inner surfaces in contact. The geometric measurements were performed using a multisensored opto-mechanical coordinate measuring machine. The following parameters were measured and compared for the CAD/CAM and stock titanium abutment groups, respectively: width of interference and interference length between the conical surfaces of the implant and abutment; and volume of material involved in the implant-abutment connection. RESULTS: Interference width mean ± SD values of 18 ± 0.5 and 14 µ 0.5 µm were calculated for the stock and CAD/CAM titanium abutment groups, respectively. The difference was statistically significant (P = .02). Furthermore, the interference length mean ± SD values of 763 ± 10 and 816 ± 43 µm were calculated for stock and CAD/CAM titanium abutment groups, respectively. The difference was also statistically significant (P = .04). Finally, the volume of material involved in the implant-abutment connection was compared between stock and CAD/CAM titanium abutment groups; the mean ± SD values of 0.134 ± 0.014 and 0.108 ± 0.023 mm3 were significantly different (P = .009). CONCLUSION: Both standard and CAD/CAM abutment groups showed a three-dimensional (3D) seal activation after the screw tightening. Nevertheless, stock titanium abutments showed a significantly higher volume of material involved in the implant-abutment connection compared with that of CAD/CAM titanium abutments.


Assuntos
Desenho Assistido por Computador , Dente Suporte , Projeto do Implante Dentário-Pivô , Implantes Dentários , Humanos , Teste de Materiais , Titânio , Zircônio
16.
Vet Surg ; 45(8): 987-995, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27716955

RESUMO

OBJECTIVE: To define and validate a method for the measurement of 3-dimensional (3D) morphometric parameters in polygonal mesh models of canine femora. STUDY DESIGN: Ex vivo/computerized model. SAMPLE POPULATION: Sixteen femora from 8 medium to large-breed canine cadavers (mean body weight 28.3 kg, mean age 5.3 years). METHODS: Femora were measured with a 3D scanner, obtaining 3D meshes. A computer-aided design-based (CAD) software tool was purposely developed, which allowed automatic calculation of morphometric parameters on a mesh model. Anatomic and mechanical lateral proximal femoral angles (aLPFA and mLPFA), anatomic and mechanical lateral distal femoral angles (aLDFA and mLDFA), femoral neck angle (FNA), femoral torsion angle (FTA), and femoral varus angle (FVA) were measured in 3D space. Angles were also measured onto projected planes and radiographic images. RESULTS: Mean (SD) femoral angles (degrees) measured in 3D space were: aLPFA 115.2 (3.9), mLPFA 105.5 (4.2), aLDFA 88.6 (4.5), mLDFA 93.4 (3.9), FNA 129.6 (4.3), FTA 45 (4.5), and FVA -1.4 (4.5). Onto projection planes, aLPFA was 103.7 (5.9), mLPFA 98.4 (5.3), aLDFA 88.3 (5.5), mLDFA 93.6 (4.2), FNA 132.1 (3.5), FTA 19.1 (5.7), and FVA -1.7 (5.5). With radiographic imaging, aLPFA was 109.6 (5.9), mLPFA 105.3 (5.2), aLDFA 92.6 (3.8), mLDFA 96.9 (2.9), FNA 120.2 (8.0), FTA 30.2 (5.7), and FVA 2.6 (3.8). CONCLUSION: The proposed method gives reliable and consistent information about 3D bone conformation. Results are obtained automatically and depend only on femur morphology, avoiding any operator-related bias. Angles in 3D space are different from those measured with standard radiographic methods, mainly due to the different definition of femoral axes.


Assuntos
Cães/anatomia & histologia , Fêmur/diagnóstico por imagem , Imageamento Tridimensional/veterinária , Radiografia/veterinária , Animais , Cadáver , Fêmur/anatomia & histologia
17.
Tissue Eng Part C Methods ; 22(2): 132-141, 2016 02.
Artigo em Inglês | MEDLINE | ID: mdl-26443415

RESUMO

By definition, osseointegration means close contact between bone and implant. Bone response is related to implant surface properties. Various surfaces have been studied and applied to improve the biological properties of the implant and thereby favor the mechanism of osseointegration. This strategy aims to promote osseointegration by means of a faster and stronger bone formation, improving stability during the healing process, and thus allowing for earlier loading of the implant. Dental implant osseointegration has so far been studied in various animal models. The development of a method based on tissue engineering for assessing the osseointegration process in vitro could prove a valid biomimetic alternative to sacrificing animals. In this study, flat cylindrical dental implants with moderately rough surfaces and machined implants were set in bovine bone blocks. Then, adipose-derived stem cells (ADSCs) were three dimensionally cultured onto these blocks in osteo-endothelial medium for up to 30 days to mimic the osseointegration process in vitro. Scanning electron microscopy (SEM) and gene expression were used to examine stem cell commitment. Mechanical pull-out tests were also performed. SEM analysis identified cells with an osteoblast morphology adhering to the surface of the implants after their removal. Gene expression analysis showed that ADSCs seeded onto the bone blocks were able to express osteoblast and endothelial markers. The implants with the moderately rough surface generated higher pull-out strengths when compared with the machined implants. Nevertheless, the pull-out test values were higher for implants placed in bone blocks with ADSCs than for those set in scaffolds without stem cells. Our results demonstrate the validity of the method adopted and its potential for use in the in vitro assessment of the biological behavior of dental implant surfaces.

18.
Clin Implant Dent Relat Res ; 17 Suppl 2: e721-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25782045

RESUMO

PURPOSE: The study aims to evaluate three-dimensionally (3D) the accuracy of implant impressions using a new resin splinting material, "Smart Dentin Replacement" (SDR). MATERIALS AND METHODS: A titanium model of an edentulous mandible with six implant analogues was used as a master model and its dimensions measured with a coordinate measuring machine. Before the total 60 impressions were taken (open tray, screw-retained abutments, vinyl polysiloxane), they were divided in four groups: A (test): copings pick-up splinted with dental floss and fotopolymerizing SDR; B (test): see A, additionally sectioned and splinted again with SDR; C (control): copings pick-up splinted with dental floss and autopolymerizing Duralay® (Reliance Dental Mfg. Co., Alsip, IL, USA) acrylic resin; and D (control): see C, additionally sectioned and splinted again with Duralay. The impressions were measured directly with an optomechanical coordinate measuring machine and analyzed with a computer-aided design (CAD) geometric modeling software. The Wilcoxon matched-pair signed-rank test was used to compare groups. RESULTS: While there was no difference (p = .430) between the mean 3D deviations of the test groups A (17.5 µm) and B (17.4 µm), they both showed statistically significant differences (p < .003) compared with both control groups (C 25.0 µm, D 19.1 µm). CONCLUSIONS: Conventional impression techniques for edentulous jaws with multiple implants are highly accurate using the new fotopolymerizing splinting material SDR. Sectioning and rejoining of the SDR splinting had no impact on the impression accuracy.


Assuntos
Resinas Compostas/uso terapêutico , Materiais para Moldagem Odontológica/uso terapêutico , Técnica de Moldagem Odontológica , Desenho Assistido por Computador , Técnica de Moldagem Odontológica/instrumentação , Planejamento de Prótese Dentária/métodos , Humanos , Imageamento Tridimensional , Técnicas In Vitro , Metilmetacrilatos/uso terapêutico , Polimerização/efeitos da radiação , Resinas Sintéticas/uso terapêutico
19.
Int J Oral Maxillofac Implants ; 28(3): 687-93, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23748298

RESUMO

PURPOSE: The purpose of this study was to investigate the marginal precision of computer numeric control-milled frameworks fabricated of grade 4 commercially pure titanium or cobalt-chrome alloy through digital technology and to compare them with conventional cast frameworks. MATERIAL AND METHODS: A titanium cast of a mandibular arch with six implant analogs was used as a master. The master cast was measured with a coordinate measuring machine. Fifteen rigid anatomic frameworks were created on the master cast in cast gold alloy and milled in titanium or cobalt-chrome material. The fifteen anatomic frameworks were measured in the same manner as the master cast. While the milled frameworks were measured once, at the end of the milling process, the cast anatomic frameworks were measured twice: immediately after the casting and divesting procedures and again after a technical adaptation procedure. Each anatomic framework was weighed. To compare the measurements obtained from each group of frameworks, descriptive statistics were calculated and one-way analysis of variance was performed, with values considered statistically significant at P < .05. RESULTS: The mean weight of the cast frameworks was 33.41 g, the cobalt-chrome frameworks weighed 18.12 g on average, and the titanium frameworks averaged 8.7 g. The mean values for three-dimensional deviation of the center point position for each group of frameworks were 261 µm (cast frameworks before adaptation), 49 µm (cast frameworks after adaptation), 26 µm (milled frameworks in cobalt-chrome), and 26 µm (milled frameworks in titanium). CONCLUSIONS: Within the limitations of this in vitro study, absolute passive fit cannot be achieved, regardless of material and fabrication technique. Anatomic milled frameworks fabricated in titanium or cobalt-chrome presented reduced center point deviation compared to cast frameworks. Titanium frameworks weighed less than cobalt-chrome and cast gold alloy frameworks.


Assuntos
Ligas de Cromo , Desenho Assistido por Computador , Técnica de Fundição Odontológica/normas , Planejamento de Prótese Dentária/normas , Prótese Dentária Fixada por Implante/normas , Mandíbula/anatomia & histologia , Titânio , Implantes Dentários , Planejamento de Prótese Dentária/métodos , Ligas de Ouro , Humanos
20.
Cranio ; 27(3): 200-10, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19697649

RESUMO

This is a case of unilateral masseter muscle hypertrophy (MMH) treated with botulinum toxin (NHAI-normalised hemi-facial asymmetry index improvement from 5.48 to 3.04). After 19 months the treatment was repeated because of hypertrophy relapse (NHAI increase up to 6.82). The volume variations in the masseter area were monitored during 25 months using a laser scanner to compute facial volume. In order to relate the cause of hypertrophy and relapse to the presence of parafunctional activities, a nocturnal electromyography (EMG) study was conducted with positive results (nocturnal parafunctions of patients 4074.99 microV to be compared with a control group value of 1644.63 microV). The lack of the left inferior molars and the consequent right occlusal support seemed to justify the hypertrophy of right masseter (MMRight-POC [percent overlapping coefficient] 91.9%). However, the prosthetic rehabilitation did not prevent relapse in the same muscle. The EMG analysis of both the muscular activation (MMRight-POC 66.0% after relapse) and inhibition activity in Maximum Voluntary Clench (MVC) resulted in contradictory conclusions. At present, the available knowledge regarding MMH physiopathology is very limited and does not support a therapeutic rationale for relapse prevention.


Assuntos
Toxinas Botulínicas Tipo A/uso terapêutico , Músculo Masseter/patologia , Doenças Musculares/patologia , Fármacos Neuromusculares/uso terapêutico , Adulto , Cefalometria , Eletromiografia , Lateralidade Funcional , Humanos , Hipertrofia/tratamento farmacológico , Masculino , Músculo Masseter/efeitos dos fármacos , Músculo Masseter/fisiopatologia , Doenças Musculares/tratamento farmacológico , Doenças Musculares/fisiopatologia , Recidiva , Falha de Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...